1. Mechanical load issue
Cause : Spindle jamming, bearing damage or severe tool wear may lead to overload alarm
Solution : Inspect the mechanical transmission part, clear any stuck foreign objects, and replace worn components.
2. Motor failure
Cause : short circuit of the motor winding, broken rotor bars or damage to the magnetic tachometer switch.
solution to : test the insulation of the motor winding and the DC resistance, and repair or replace the motor; Check and adjust the installation distance of the magnetic tachometer switch (0.1 to 0.15mm).
3. Driver failure
Cause : damage to the power module, abnormality in the current detection circuit or improper parameter setting
solves :
Check the driver alarm code and repair or replace the faulty module
Reset reasonable overload protection parameters and acceleration and deceleration times
Confirm the selection of the common power supply (PS) and check the input power supply voltage
4. Issues with the cooling system and power supply
Cause : The cooling fan is damaged, the heat sink is clogged, or the power supply voltage is abnormal
Solution : Clean the cooling system and replace the damaged fan; Check the power line and stabilize the input voltage
5. System parameters and alarm shielding
Cause : Incorrect parameter Settings or turret alarm prevent the spindle from rotating
solves :
Enter the parameter interface and adjust the relevant parameters (for example, change the 2808 parameter to 05)
Shielding the alarm by ladder diagram (e.g., disconnecting the 246.3 alarm coil)
6. Encoder and Feedback Signal
Cause : loss of encoder signal or poor connection
solution : Check the encoder cable and reinsert the connector; Replace the damaged encoder.
General exclusion steps
Check the alarm code : determine the fault type according to the prompts on the control panel
Consult manual : Refer to the equipment manual or online resources for specific solutions
Check the power supply and connection : ensure that the power supply voltage is normal and the motor and driver are firmly connected
Contact technical support : if the problem remains unsolved, contact the manufacturer for professional assistance
Precautions
When modifying parameters or shielding alarms, it should be done in the emergency stop state, and the modified position should be recorded for restoring
Non-professionals are advised to seek technical support to avoid further damage to the equipment